How to Set Up Door/Window Sensors:
Preprogrammed sensors have unique properties built in. Door sensors have an entry delay of 30 seconds, and an exit delay of 60 seconds. Window sensors have an entry delay of 0 seconds. Ensure you place them in the correct locations.
 
Once you have determined the appropriate location and orientation of the Bracket and Magnet, use the double-sided tape to mount the sensor to the door/window
Note: Various orientations between the Bracket and Magnet may be used as long as 3/4” distance is not exceeded. Click here to view the standard sensor components.
 
WHEN POSSIBLE, PLACE THE BRACKET ON THE STATIONARY FRAME OF THE DOOR OR WINDOW, AND PLACE THE MAGNET ON THE DOOR OR WINDOW ITSELF
 
To Change Preprogrammed Sensors:
A.  Press MENU on the Console
B.  Scroll to Security Setup, press SELECT
C.  Enter Master Code*
D.  Scroll to Sensors, press SELECT
E.  SELECT the sensor to be modified
F.  Use the menu to select and change sensor attribute
 
To Add Additional Sensors:
H. Remove the battery tab by squeezing and holding the metal spring clip where REMOVE tab folds around battery.
Note: The battery will spring upward. Carefully remove the insulating tab from under the battery, then gently press the battery back into the spring clip
I.   Press MENU on the Console
J.  Scroll to Security Setup, press SELECT
K.  Enter Master Code*
L.  Scroll to Sensors, press SELECT
M. Scroll to Add New, press SELECT
N. Scroll to Standard Sensor, press SELECT
O. Wait 5 seconds before clipping Sensor the Bracket. You will then have 30 seconds to complete setup
P. Clip Sensor into Bracket. The Console will beep when system finds the Sensor. This may take a few seconds. Press OK
Note: If “SENSOR OUT OF RANGE” is displayed, the Sensor is too far away from the closest Grid Controller (Base, Console, Grid Extender or Cellular Gateway): 
Q. Edit Sensor Name (Optional)
- To change Sensor Name, press DELETE key to remove default name
- Using keys on Console keypad, type in desired name
- Press OK when complete
R. Select Sensor Placement: Scroll to Door or Window. Press OK
S. Select Alarm Type: Scroll to Stay & Away, Away Only, or Convenience. Press OK
T. With the system disarmed, test your Sensor by opening the door or window. Correct setup will generate a chime sound

 
*Master Code is found on the inside cover of your Quick Setup Guide